Turbidity
Information Available for Monday, August 2, 2010
Discharge from the
sedimentation basin was initiated at 7:30 am based on visual observations of
the water in the sedimentation basin. The observations clearly showed a
reduction in turbidity in the basin and clear water was observed to at least
a 1-2 foot depth. Discharge was permitted to continue after a reading of
48.3 NTUs was collected at the discharge pipe. Six turbidity readings were
collected at the discharge point throughout the morning with results all
well below the turbidity standard (highest result was 53.9 NTUs). The
monthly discharge sample for August for total and dissolved lead analysis
was collected at 11:20 am. The turbidity at the time of sample collection
was 6.36 NTUs.
Dissolved lead was not
detected at a detection limit of 1 ug/L. The NPDES permit standard for
maximum dissolved lead for the Site is 650 ug/L. Total lead was also not
detected at a detection limit of 1 ug/L. There is not an NPDES standard for
total lead. These results confirm that
the turbidity performance standard is protective against a release of lead
into the Lackawanna River.
(Click here to go back to the
August 2010 stormwater calendar page.)
Page Last Modified
Wednesday January 12, 2011 02:11:54 PM
|